Model |
|
E-AIR T900 |
E-AIR T900 |
Frequency |
Hz |
60 |
50 |
Minimum effective receiver pressure |
PSI |
58 |
58 |
Maximum effective receiver pressure |
PSI |
150 |
150 |
Maximum ambient temperature |
°C (°F) |
45 (113) |
45 (113) |
Minimum ambient temperature |
°C (°F) |
0 (32) |
0 (32) |
Motor shaft speed (rpm) |
rpm |
1790 |
2890 |
Free air delivery |
|
|
|
Effective working pressure (bar(g)) 4 |
CFM (l/s) |
903 (426) |
903 (426) |
Effective working pressure (bar(g)) 5 |
CFM (l/s) |
896 (423) |
896 (423) |
Effective working pressure (bar(g)) 6 |
CFM (l/s) |
896 (423) |
896 (423) |
Effective working pressure (bar(g)) 7 |
CFM (l/s) |
896 (423) |
896 (423) |
Effective working pressure (bar(g)) 8 |
CFM (l/s) |
884 (417) |
884 (417) |
Effective working pressure (bar(g)) 9 |
CFM (l/s) |
879 (415) |
879 (415) |
Effective working pressure (bar(g)) 10 |
CFM (l/s) |
875 (413) |
875 (413) |
Effective working pressure (bar(g)) 10,4 |
CFM (l/s) |
871 (411) |
871 (411) |
Total electrical power input (kW) |
|
|
|
Effective working pressure (bar(g)) 4 |
kW (HP) |
151 (202) |
159 (213) |
Effective working pressure (bar(g)) 5 |
kW (HP) |
159 (213) |
162 (217) |
Effective working pressure (bar(g)) 6 |
kW (HP) |
161 (216) |
169 (226) |
Effective working pressure (bar(g)) 7 |
kW (HP) |
169 (227) |
178 (239) |
Effective working pressure (bar(g)) 8 |
kW (HP) |
177 (237) |
186 (249) |
Effective working pressure (bar(g)) 9 |
kW (HP) |
185 (248) |
194 (260) |
Effective working pressure (bar(g)) 10 |
kW (HP) |
194 (260) |
204 (274) |
Effective working pressure (bar(g)) 10,4 |
kW (HP) |
195 (261) |
205 (275) |
Unload |
kW (HP) |
74 (99) |
74 (99) |
Total electrical power input at unload |
kW (HP) |
78 (105) |
79 (106) |
Compressed air temperature at outlet valve |
°C(°F) |
Amb. +16°C +/- 7°C (Amb. +61°F +/- 45°F) |
Amb. +16°C +/- 7°C (Amb. +61°F +/- 45°F) |
Fan(s) shaft power |
kW (HP) |
4 (5) |
4 (5) |
Frequency |
kW (HP) |
4 (5) |
5 (6.7) |
DESIGN DATA |
|
|
|
Drive motor installed power |
kW |
9160 kW (220 HP-cv) |
160 kW (220 HP-cv) |
Drive motor name |
|
Motor 3Ph W22 WEG |
Motor 3Ph W22 WEG |
Housing |
|
315S/M |
315S/M-02 |
Motor shaft speed |
rpm |
1790 |
2980 |
Voltage |
|
380/440/460/575 Volts |
400 Volts |
Current |
A |
297/256/243/194 |
264 |
Service Factor |
|
1,2 |
1,2 |
Ip/In |
|
8 |
8 |
I.P. |
|
IPW55 |
IPW55 |
Fan motor name |
|
AT112S-4 |
AT112S-4 |
Housing |
|
112M |
112M |
Motor shaft speed |
rpm |
1740 |
1460 |
Voltage |
|
220/380/440/460/575 |
400V |
Current |
A |
14,2/8,24/7,11/6,6/ |
8,32 |
Service Factor |
|
1 |
1,15 |
Ip/In |
|
7 |
8,2 |
I.P. |
|
IP55 |
IP55 |
Shipping mass – 50 Hz wet |
Kg (Ib) |
|
3160 (6967) |
Shipping mass – 50 Hz net |
Kg (Ib) |
|
3105 (6845) |
Shipping mass – 60 Hz wet |
Kg (Ib) |
2963 (6532) |
|
Shipping mass – 60 Hz net |
Kg (Ib) |
2908 (6411) |
|
Shipping mass – Option DDx/PDx filters |
Kg (Ib) |
40 (88) |
40 (88) |
Shipping mass – Weight Undercarriage |
Kg (Ib) |
517 (1140) |
517 (1140) |