Wacker Neuson IEC High-frequency internal vibrator

Practical and flexible

The Wacker Neuson IEC high-frequency internal vibrator combines two machines in one with an integrated frequency converter, offering flexibility, easy handling, and an ergonomic design at an affordable price. Engineered in Germany, it delivers consistent high RPMs for reliable concrete consolidation and reduces maintenance costs.

Description

The IEC High-Frequency Internal Vibrator is a versatile and efficient solution designed to meet the rigorous demands of modern construction sites. This advanced electric concrete vibrator combines flexibility, durability, and user-friendly features to ensure optimal concrete consolidation for a variety of applications.

Integrated Frequency Converter for Enhanced Portability

The IEC series features an integrated frequency converter, effectively combining two machines into one compact unit. This design eliminates the need for additional equipment, streamlining operations and enhancing portability across the job site. Operators can easily transport and deploy the vibrator, reducing setup time and increasing productivity.

High-Performance Electric Motor with Stable Speeds

At the core of the IEC High-Frequency Internal Vibrator is a robust electric motor developed and manufactured in-house by Wacker Neuson in Germany. This motor maintains consistently high RPMs, delivering reliable and efficient concrete consolidation even under demanding conditions. Precision engineering ensures long-term performance and minimal maintenance requirements.

Ergonomic Design for User Comfort

Understanding the physical demands of construction work, the IEC series is designed with operator comfort in mind. The ergonomic handle and lightweight construction reduce fatigue during extended use, allowing for more precise control and improved job performance. This thoughtful design ensures that operators can work efficiently without unnecessary strain.

Durable Construction with Tempered Vibrator Head

Durability is a key feature of the IEC High-Frequency Internal Vibrator. The front third of the vibrator head is fully tempered, providing exceptional resistance to wear and extending the service life of the equipment. This robust construction ensures that the vibrator can withstand the harsh conditions typical of construction sites, offering a cost-effective solution through reduced maintenance needs.

Enhanced Safety with Portable Residual Current Device (PRCD)

Safety is paramount in the IEC series design. Each unit is equipped with a Portable Residual Current Device (PRCD) housed within the cover. This protective ground fault interrupter continuously monitors the electrical current flow, providing secure protection for both the operator and the machine. In the event that safety guidelines for the power source are not observed, the PRCD intervenes to prevent potential hazards, ensuring compliance with safety standards.

Key Features:

Integrated Frequency Converter: Combines two machines in one compact unit, eliminating the need for additional equipment and enhancing portability.
High-Performance Electric Motor: Developed and manufactured in Germany, ensuring consistent high-speed operation and reliable concrete consolidation.
Ergonomic Design: Lightweight construction with an ergonomic handle reduces operator fatigue and improves control during extended use.
Tempered Vibrator Head: The front third of the head is tempered for increased durability and reduced maintenance costs.
Portable Residual Current Device (PRCD): Provides continuous monitoring of electrical current flow, enhancing safety for both the operator and the equipment.

The IEC High-Frequency Internal Vibrator stands as a testament to Wacker Neuson’s commitment to quality and innovation. Its combination of advanced features, ergonomic design, and robust construction makes it an indispensable tool for professionals seeking efficient and reliable concrete consolidation solutions. Upgrade your equipment today to experience the superior performance and safety of the IEC series.

IEC45/120/3 US

Model Variations IEC45/120/3 US
Nominal current 8A
Nominal voltage 120 V
Nominal frequency 50-60 Hz
Nominal power [P] 0.56 KW
Phase 1 ~
Head diameter/- diagonal 1.8″
Length Hose 9.8 Foot
Weight 23.81 lb
Rubber cap no
Motor type Asynchronous motor
Length Cable 16.4 Foot
Kind of plug NEMA 5-15P (TypeB)
Protection class I / Protective earthing
Degree of protection IP67

IEC45/120/8 US

Model Variations IEC45/120/8 US
Nominal current 8A
Nominal voltage 120 V
Nominal frequency 50-60 Hz
Nominal power [P] 0.56 KW
Phase 1 ~
Head diameter/- diagonal 1.8″
Length Hose 26.2 Foot
Weight 32.19 lb
Rubber cap no
Motor type Asynchronous motor
Length Cable 16.4 Foot
Kind of plug NEMA 5-15P (TypeB)
Protection class I / Protective earthing
Degree of protection IP67

IEC58/120/3 US

Model Variations IEC58/120/3 US
Nominal current 10A
Nominal voltage 120 V
Nominal frequency 50-60 Hz
Nominal power [P] 0.72 KW
Phase 1 ~
Head diameter/- diagonal 2.3″
Length Hose 9.8 Foot
Weight 31.09 lb
Rubber cap no
Motor type Asynchronous motor
Length Cable 16.4 Foot
Kind of plug NEMA 5-15P (TypeB)
Protection class I / Protective earthing
Degree of protection IP67

IEC58/120/8 US

Model Variations IEC58/120/8 US
Nominal current 10A
Nominal voltage 120 V
Nominal frequency 50-60 Hz
Nominal power [P] 0.72 KW
Phase 1 ~
Head diameter/- diagonal 2.3″
Length Hose 26.2 Foot
Weight 42.33 lb
Rubber cap no
Motor type Asynchronous motor
Length Cable 16.4 Foot
Kind of plug NEMA 5-15P (TypeB)
Protection class I / Protective earthing
Degree of protection IP67